Hybrid set 3ph. SH10RT + SBR224 (22.4kWh)

https://www.elektromodus.lt/web/image/product.template/309/image_1920?unique=db3872f

Nominal power: 10 kW
MPPT: 2+1
Maximum. DC input power: 15000W
Maximum efficiency: 98.4%
MPPT Input voltage range: 200-950V
Maximum DC input voltage: 1000V
Protection class: IP65
Dimensions: 460 × 540 × 170 mm
Weight: 27 kg
Control: Led indicator, app, website
Manufacturer's warranty: 10 years.

Hybrid solar plant

Hybrid 3Ph. Inverter:

Sungrow SH10RT

Batteries: 

SBR 224

10,966.59 € 10966.59 EUR 10,966.59 € VAT included

10,966.59 € VAT included

This combination does not exist.


SUNGROW

CLEAN POWER FOR ALL


BLACK-START CAPABLE

Nothing to worry about! In the event of a power failure, the 3-phase hybrid inverter automatically

switch to backup mode - you won't notice or feel the process. In less than 20ms, the backup switch will open and the load connected to the backup port up to 9.9 kW will be powered by Batteries and Solar power.​

ALWAYS AVAILABLE

About 14,700 power outages are reported in Europe per year. But this is something you don't have to worry about anymore! During power supply, a 3-phase hybrid inverter can power a selected household load with true 3-phase backup power.

LOWER COST

The best thing about it? No need for any external backup box.

More possibilities. More power. More security. Less costs. Hybrid inverter - for you.

Blackout?
No, thanks.

Give your daily life an uninterrupted flow of energy, even in the event of a power outage, as the most advanced solar hybrid inverters and battery storage solutions take care of continuing to power your devices.


BACKUP FUNCTION?

YES, NOW POSSIBLE!

​A 3-phase hybrid can divert up to 3.3 kVA per phase from the mains to the backup port in continuous mode. Normal operation on the network allows the user to supply power to all loads from the mains, even the device that connects to the spare port.


GRID PARALLEL OPERATION

The backup switch inside the inverter is closed. Grid-parallel loads (blue) as well as back-up loads (orange) are fed from the grid. Both circuits may share the same transfer case but

should be protected on their AC side by a circuit breaker and an RCD.


BACKUP MODE


In the event of a power grid failure, the backup switch inside the 3-phase hybrid opens and all loads connected to the backup port will have a smooth transition to backup mode. Only loads not connected to the backup switch will have no power supply.


We invite you to familiarize yourself with the technical documentation of the current converter, where you will find all the necessary information. Below are the data sheets in Lithuanian, if you want to see the parameters in English, click on the link marked below this text. 

​​​​Technical datasheet in English language: Sungrow Hybrid inverter​​​​  

Technical datasheet in English language: Sungrow battery